7.15. Bad main functioning of devices of control, his reasons and ways of elimination

Defect cause
Elimination way
The tacômetro does not work
The security lock n ° 7 merged
(in 10 A)
To check the lack of the short circuit and to substitute a lock of security
Bad functioning of a tacômetro
To check a tacômetro
Bad driving functioning
To remove the bad functioning
The rate of the level of the fuel does not work
The security lock n ° 7 merged
(in 10 A)
To check the lack of the short circuit and to substitute a lock of security
Bad functioning of the rate
To check the rate
Bad functioning of the sensor of level of fuel
To check the sensor
Bad driving functioning
To remove the bad functioning
The lamp of control of a reserve of the fuel is not burned
The security lock n ° 7 merged (in 10 A)
To check the lack of the short circuit and to substitute a lock of security
The lamp merged
To substitute a lamp
Bad functioning of the sensor of level of fuel
To check the sensor
Bad functioning of driving or violation
connections with "weight"
To remove the bad functioning
The rate of the temperature of cooling the liquid does not work
The security lock n ° 7 merged
(in 10 A)
To check the lack of the short circuit and to substitute a lock of security
Bad functioning of the rate
To check the rate
The bad functioning of the sensor of the temperature of cooling the liquid
To check the sensor
Bad functioning of driving or violation of connection with "weight"
To remove the bad functioning
The lamp of control of the pressure of oil is not burned
The security lock n ° 7 merged
(in 10 A)
To check the lack of the short circuit and to substitute a lock of security
The lamp merged
To substitute a lamp
Bad functioning of the sensor of pressure of oil
To check the sensor
Bad functioning of driving or violation of connection with "weight"
To remove the bad functioning
The lamp of control of the level of fluid of brake is not burned
The security lock n ° 7 merged
(in 10 A)
To check the lack of the short circuit and to substitute a lock of security
The lamp merged
To substitute a lamp
Bad functioning of the sensor of level of fluid of brake
To check the sensor
Bad functioning of the sensor of the brake of parking
To check the sensor
Bad functioning of driving or violation of connection with "weight"
To remove the bad functioning
The lamp of control of an open door is not burned
The security lock n ° 29 merged
(in 15 A)
To check the lack of the short circuit and to substitute a lock of security
The lamp merged
To substitute a lamp
Bad functioning of the sensor of door
To check the sensor
Bad functioning of driving or violation of connection with "weight"
To remove the bad functioning
The lamp of control of the fixed burns of belt of seat
The security lock n ° 7 merged
(in 10 A)
To check the lack of the short circuit and to substitute a lock of security
The lamp merged
To substitute a lamp
Bad functioning of the sensor of a belt
To check the sensor
Bad functioning of driving or violation of connection with "weight"
To remove the bad functioning